Whirlpool Gas Dryer #GGW9200LW0 is not heating up - how to test your electronic control board #8530589

If your gas dryer GGW9200LW0 is not heating up, then you may want to test your Electronic Control Board.

Your dryer electronic control board (timer) (see image 6) is located in the control panel. If your 5 parts (igniter, thermo fuse, hi - limit thermostat, flame sensor and the two gas solenoid coils) all are tested fine, your drum tumbles and your dryer still not heating up, then your control board (display) is bad. The manufacturer part number for control board is 8530589. And you can get it from Appliance Parts Pros. If you are not sure about that, then you may want to consider calling an appliance technician person to test it for you before you make any purchase, or perhaps buying a new dryer.

And finally, let’s check your dryer vent. Make sure it’s clean and not clogged up with lint, or the vent is kinked. Also clean inside you dryer, remove your lint screen and get a long brush to clean inside where the screen goes. Don’t be afraid to use your vacuum.

Look up your own dryer.

Here below you can enter your model number to find the exact part number for your dryer.